Vorliegende Sprache |
eng |
Hinweise auf parallele Ausgaben |
381483649 Buchausg. u.d.T.: ‡Hygrothermal behavior, building pathology and durability |
ISBN |
978-3-642-31157-4 |
Name |
Freitas, Vasco Peixoto ¬de¬ |
Delgado, João M. P. Q. |
ANZEIGE DER KETTE |
Delgado, João M. P. Q. |
T I T E L |
Hygrothermal Behavior, Building Pathology and Durability |
Verlagsort |
Berlin, Heidelberg |
Verlag |
Springer |
Erscheinungsjahr |
2013 |
2013 |
Umfang |
Online-Ressource (VIII, 232 p. 187 illus, digital) |
Reihe |
Building Pathology and Rehabilitation ; 1 |
Notiz / Fußnoten |
Description based upon print version of record |
Weiterer Inhalt |
Hygrothermal Behavior,Building Pathology andDurability; Preface; Contents; 1 Reducing the Risk of Microbial Growth on Insulated Walls by Improving the Properties of the Surface Materials; Abstract; 1…Introduction; 2…Growth Conditions; 3…Assessment of the Risk for Microbial Growth; 4…Computational Investigations; 4.1 Validation; 4.2 Influence of Construction Type and Orientation; 4.3 Computations of Prevention Strategies; 4.3.1 Influence of the Thickness of the Plaster; 4.3.2 Influence of Irradiative Properties of the Surface; 4.3.3 Using Phase Change Materials. 4.3.4 Combination of PCM and IR-Effect4.3.5 Comparison of Measures to Reduce the Amount of Condensation; 4.3.6 Improvement of the Hygric Material Properties; 5…Field Tests; 5.1 Influence of Construction Type; 5.2 Use of PCM and Low-E Paint; 5.3 Influence of Hygric Material Properties; 6…Summary; References; 2 Biological Defacement of External Thermal Insulation Composite Systems; Abstract; 1…Introduction; 2…Experimental Study; 2.1 Setting Up the Test; 2.2 Results; 2.2.1 Surface Temperature; 2.2.2 Exterior Surface Condensation; 2.2.3 Wind-Driven Rain; 2.3 Discussion of the Results. 2…Materials and Methods2.1 Biological Assessment of Long Term Exposed Specimen; 2.2 Biological Mode of Action of Investigated Biocides; 2.3 Investigation of a Possible Biocide Tolerance of Isolated Algae Strains; 3…Results; 3.1 Biological Assessment of Long Term Exposed Specimen; 3.2 Investigation of a Possible Biocide Tolerance of Isolated Algae Strains; 4…Discussion; Acknowledgments; References; 4 Hygrothermal Conditions and Mould Growth Potential in Cold Attics: Impact of Weather, Building System and Construction Design Characteristics; Abstract; 1…Introduction. 2…Probabilistic Analysis of the Attic Using Simplified HAM-Model2.1 Thermal Model; 2.2 Moisture Model; 2.3 Mould Growth Model; 2.4 Results of Monte Carlo Simulations; 3…Hygrothermal Analysis of the Attic Using Advanced HAM-Model; 3.1 Advanced HAM-Model of the Attic; 3.1.1 Heat and Moisture Balance in the Attic; 3.1.2 Ventilation of the Attic; 3.1.3 Ventilation and Air Infiltration in the House; 3.1.4 Air Mass Balance in the House and in the Attic; 3.2 Comparison of the Simple and the Advanced Model; 3.3 Alternative Technical Solution for Cold Attics; 4…Adaptive or Controlled Ventilation. 4.1 Field Studies of One-Family Houses in Stockholm. 3…Numerical Simulation3.1 Parameters of the Numerical Simulation; 3.2 Discussion of the Results; 3.2.1 Surface Temperature; 3.2.2 Exterior Surface Condensation; 3.2.3 Wind-Driven Rain; 4…Hygrothermal Model to Assess the Risk of Biological Growth; 4.1 Assessing Exterior Surface Condensation; 4.2 Assessing WDR; 4.3 Assessing the Drying Process; 4.4 The Model BIO.MOD; 5…Validation of the Model BIO.MOD; 6…Risk Map of Biological Defacement in Portugal; 7…Conclusions; Acknowledgments; 3 Effectiveness and Durability of Biocides in Building Coatings: Biological Aspects; Abstract; 1…Introduction |
Titelhinweis |
Buchausg. u.d.T.: ‡Hygrothermal behavior, building pathology and durability |
ISBN |
ISBN 978-3-642-31158-1 |
ISBN 1-283-63090-7 ebk |
ISBN 978-1-283-63090-0 MyiLibrary |
Klassifikation |
TNK |
TEC009020 |
TEC021000 |
691 |
TA401-492 |
Kurzbeschreibung |
The main purpose of this book, Hygrothermal, Building Pathology and Durability, is to provide a collection of recent research works to contribute to the systematization and dissemination of knowledge related to construction pathology, hygrothermal behaviour of buildings, durability and diagnostic techniques and, simultaneously, to show the most recent advances in this domain. It includes a set of new developments in the field of building physics and hygrothermal behaviour, durability approach for historical and old buildings and building pathology vs. durability. The book is divided in several chapters that are a resume of the current state of knowledge for benefit of professional colleagues, scientists, students, practitioners, lecturers and other interested parties to network. |
1. Schlagwortkette |
Gebäude |
Thermische Belastung |
Feuchtigkeit |
Mikrobiologische Korrosion |
Alterungsbeständigkeit |
Aufsatzsammlung |
1. Schlagwortkette ANZEIGE DER KETTE |
Gebäude -- Thermische Belastung -- Feuchtigkeit -- Mikrobiologische Korrosion -- Alterungsbeständigkeit -- Aufsatzsammlung |
2. Schlagwortkette |
Gebäude |
Thermische Belastung |
Feuchtigkeit |
Mikrobiologische Korrosion |
Alterungsbeständigkeit |
ANZEIGE DER KETTE |
Gebäude -- Thermische Belastung -- Feuchtigkeit -- Mikrobiologische Korrosion -- Alterungsbeständigkeit |
SWB-Titel-Idn |
37343393X |
Signatur |
Springer E-Book |
Bemerkungen |
Elektronischer Volltext - Campuslizenz |
Elektronische Adresse |
$uhttp://dx.doi.org/10.1007/978-3-642-31158-1 |
Internetseite / Link |
Volltext |
Siehe auch |
Inhaltsverzeichnis |
Siehe auch |
Inhaltstext |
Siehe auch |
Volltext |
Siehe auch |
Cover |